{"product_id":"control-board-ultratemp-pentair-472734","title":"Pentair 472734 Control Card Set for UltraTemp and ThermalFlo Titanium","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eRestore the operation of your pool heat pump with the\u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ePentair control board kit 472734\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Designed for certain Pentair UltraTemp and ThermalFlo Titanium heat pumps, this kit allows replacement of a defective, damaged, or unstable electronic control.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePart 472734 includes the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eelectronic control board, control panel face, and corresponding label\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. It manages temperature and communication with several essential heat pump components.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePentair lists this reference under the official description \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eBezel, Control Board \u0026 Label Kit\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e in the UltraTemp replacement parts list.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eComplete control kit for heat pump\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe control board acts as the command center of the heat pump. It processes information from sensors and safety devices to manage heating sequences.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eMain functions\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eWater temperature management\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eControl of heating cycles\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCommunication with sensors\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMonitoring of safety devices\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eManagement of messages and diagnostic codes\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCoordination of the main heat pump components\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDisplay of parameters on the control panel\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eReplacing the board can restore normal operation of a device with a confirmed electronic issue.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eContents of the Pentair 472734 kit\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eReference 472734 corresponds to a replacement kit including the main components of the control interface.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eIncluded components\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eElectronic control board\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eControl panel face or bezel\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eControl panel identification label\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eSensors, wiring harnesses, relays, contactors, and other internal components are sold separately unless otherwise indicated.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eCompatibility\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis kit is intended for certain Pentair pool and spa heat pumps.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eIndicated compatibility\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCertain Pentair UltraTemp heat pumps\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCertain Pentair ThermalFlo Titanium heat pumps\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInstallations using Pentair reference 472734\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe current Pentair documentation lists part 472734 in the UltraTemp replacement parts section.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eRecommended verification\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBefore ordering, check:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eThe exact model of the heat pump\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eThe serial number\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eThe year of manufacture\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eThe number printed on the existing board\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eThe arrangement of connectors\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eThe electrical configuration of the device\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCompatibility with the control panel\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eSome UltraTemp heat pumps have had component changes depending on their year of manufacture. Validation using the serial number is therefore recommended.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003ePrecise temperature management\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe electronic board receives data from the water temperature sensor and controls the heat pump operation according to the selected temperature.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIt notably contributes to:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eMaintain the programmed temperature\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eStart or stop heating\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDisplay operating parameters\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDetect certain anomalies\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProtect the system when conditions do not allow safe operation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCommunicate with compatible equipment\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eUltraTemp systems have an electronic control with display and diagnostic functions to monitor the heat pump's operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eWhen to replace the control board?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eReplacement may be necessary when:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eThe screen no longer lights up\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eThe buttons no longer respond\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eThe display is incomplete or unstable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eThe heat pump no longer responds to settings\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eThe displayed temperature is erratic\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eError codes persist despite component checks\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eThe board shows signs of corrosion or overheating\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eElectrical damage is visible\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eA technician has confirmed an electronic failure\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA heat pump that no longer works does not automatically mean the control board is defective. Sensors, safety devices, water flow, power supply, and other components must also be checked.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eProfessional diagnosis recommended\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBefore replacing the part, a technician should confirm:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003ePresence of an adequate power supply\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCondition of fuses and connections\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOperation of the temperature sensor\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOperation of the flow detector or water pressure switch\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCondition of the refrigerant circuit pressure switches\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eContinuity of electrical harnesses\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAbsence of corrosion or water infiltration\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCompatibility of the new board\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis check reduces the risk of unnecessarily replacing a still functional board.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eInstallation by a qualified technician\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eInstalling the Pentair 472734 assembly requires opening the heat pump's electrical compartment.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eImportant recommendations\u003c\/span\u003e\u003c\/h3\u003e\n\u003col start=\"1\"\u003e\n\u003cli\u003e\u003cspan\u003eCompletely cut off the power supply.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eConfirm the absence of voltage before touching the components.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePhotograph existing connections.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIdentify each wire and connector.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCarefully remove the old board.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInstall the new board and its front panel.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eReconnect connectors to the appropriate locations.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCheck configuration and settings.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePower the device back on.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTest the heating and safety devices.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eInstallation must be performed by a qualified technician familiar with Pentair pool heat pumps. Incorrect wiring can damage the board or other electrical components.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eMain features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eElectronic control kit for heat pump\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBrand Pentair\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePart number: 472734\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOfficial description: Bezel, Control Board \u0026 Label Kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eElectronic board included\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eControl front panel included\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePanel label included\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCompatible with certain UltraTemp heat pumps\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCompatibility indicated with certain ThermalFlo Titanium\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHeating and temperature management\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eReplacement of a defective electronic control\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProfessional installation recommended\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eProduct\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eControl board kit for heat pump\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003ePentair\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003ePart number\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e472734\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eManufacturer description\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBezel, Control Board \u0026 Label Kit\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eMain contents\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eControl board, front panel, and label\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003ePrimary compatibility\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eCertain Pentair UltraTemp heat pumps\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eAdditional compatibility indicated\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eCertain Pentair ThermalFlo Titanium heat pumps\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eApplication\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003ePool and spa heat pumps\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eFunction\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eTemperature control and operation sequence management\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003ePart type\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eReplacement electronic kit\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eInstallation\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBy a qualified technician\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003ePackage contents\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e1 Pentair control board\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e1 control panel front\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e1 control label\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eKit reference 472734\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eSensors, cables, contactors, relays, transformers, and other components are sold separately unless otherwise indicated.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eRestore control of your Pentair heat pump\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe\u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ePentair control board kit 472734\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e constitutes a complete solution to replace a defective control interface on a compatible heat pump. With its electronic board, front panel, and included label, it restores temperature management and the main control functions of the device.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAvailable now at Piscine Hippocampe.\u003c\/span\u003e\u003c\/p\u003e","brand":"Pentair","offers":[{"title":"Default Title","offer_id":34018907652236,"sku":"PENT472734","price":789.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0366\/1846\/9516\/products\/81Jmtgj_S-L._AC_SL1500.jpg?v=1594838643","url":"https:\/\/piscinehippocampe.ca\/en\/products\/control-board-ultratemp-pentair-472734","provider":"Piscine Hippocampe","version":"1.0","type":"link"}